NIST26 Ships With 35,000 New EI Spectra and 68,635-Entry Tandem Library
NIST26 adds 35,000 compounds to the EI Library (now 382,180+ entries) and 17,000 to the Tandem Library, extending a reference resource used since 1988 for unknown-substance identification.
By Grace Kim2 min read423 words
Features
- NIST26 adds roughly 35,000 compounds to the Electron Ionization Library, for a total of over 382,180 entries.
- The Tandem Library gains 17,000 compounds, reaching 68,635 substances for nonvolatile, liquid-soluble analysis.
- The library, formally Standard Reference Database 1A, has been in use since 1988 and ships preinstalled on many commercial mass spectrometers.

The National Institute of Standards and Technology has released NIST26, the latest revision of its Mass Spectral Library — formally Standard Reference Database 1A — adding roughly 35,000 new compounds to the Electron Ionization (EI) Library, bringing that collection to more than 382,180 entries. The Tandem Library, which covers nonvolatile compounds dissolved in liquids, gains 17,000 compounds for a total of 68,635 substances.
Industry experts, forensic scientists, and manufacturers have used the library since 1988 to identify unknown substances in food, drugs, cosmetics, environmental samples, and even meteorites. The library ships preinstalled on many commercial mass spectrometers, and users can purchase the update through their instrument manufacturer or independent distributors.
The identification method rests on well-understood physics. A mass spectrometer ionizes a compound and fragments it into charged pieces, then sorts those fragments by mass-to-charge ratio. The resulting bar-chart-like mass spectrum is unique to that chemical. An analyst who measures a spectrum of an unknown substance can search it against the NIST library to find a match.
"Just as a person may be identified by comparing their DNA to a database, a chemical compound may be identified by comparing its mass spectrum to the NIST database," said Bill Wallace, group leader of NIST's Mass Spectrometry Data Center.
The two library components serve distinct analytical regimes. The EI Library holds fingerprints of compounds that vaporize readily, which suits gas chromatography–mass spectrometry workflows common in environmental and forensic screening. The Tandem Library addresses nonvolatile, liquid-soluble compounds — increasingly the domain of LC-MS/MS instrumentation in pharmaceutical and metabolomics work. A lab's choice of ionization method determines which library it depends on, and NIST26 expands coverage on both fronts.
One caution for measurement professionals: the library contains mass spectra measured by NIST scientists, and the institute vets each update through a comprehensive, software-based evaluation process informed by decades of experience. Match quality in the field still depends on how closely a user's instrument conditions — ionization energy, fragmentation behavior, and sample preparation — reproduce the reference measurement conditions.
NIST describes the collection as one of the world's largest mass spectral databases. The Mass Spectrometry Data Center has also updated its website at chemdata.nist.gov, where interested users can find further details on the release.
The open question for instrument buyers: will your vendor's next firmware and software update bundle NIST26, and how quickly can your lab validate the new entries against your own reference standards before putting them into routine identification workflows?
via chemdata.nist.gov (Original)
Filed under
- mass-spectrometry
- nist
- spectral-library
- chemical-identification
- analytical-chemistry
More from Grace Kim
Show full bio
Correspondent covering consumer brands and retail at Testbench Report.
21 articles
Application notes
- NIST RM 8043 Brings Degraded DNA and Mixtures to Forensic Labs
- Lab Equipment Services Head to $35.4B by 2030
- NIST Releases Five-Swatch Textile Standard for NIR Fiber ID
- UNDP and Sri Lanka's Environment Ministry Deliver Lab Equipment for Chemicals Management
- NIST Team Identifies Sizing Error That Skews Nanomaterial Data