Technical newsheet

Industrial IoT & MonitoringDevice profile

Siemens LOGO! Modules Automate Multi-Level Microalgae Farms

After seven years at the Tiszasziget pilot farm, Int-Energia and Metaplasma ship an automated control system for larger vertical photobioreactors, with per-level pH, CO2 and temperature control.

By Sophie Lindqvist4 min read730 words

Features

  • The Tiszasziget, Hungary pilot vertical farm has seven years of operating experience and runs three independent reactor levels.
  • The new medium preparation and photobioreactor filling subsystem is built on Siemens LOGO! modules.
  • Next-generation control subsystems regulate pH, temperature, lighting, CO2 supply and mixing air independently per level.
  • Harvested nutrient solution is either returned to reactors or treated by reverse osmosis, with purified water routed to reserve tanks for reuse.
  • Int-Energia Kft. and Metaplasma S.L. developed the system; AlgaFarms, a division of Int-Energia, sells the vertical farms.
How Automation Improves Microalgae Production In Vertical Photobioreactors
Device photoHow Automation Improves Microalgae Production In Vertical Photobioreactors — dangquangn / pixabay

The pilot vertical farm in Tiszasziget, Hungary has run for seven years, and that operating record now underpins an automated microalgae cultivation process control system built by Int-Energia Kft. and Metaplasma S.L. for a new generation of larger-volume photobioreactors. The system ships as part of the vertical farm itself, with AlgaFarms, a division of Int-Energia, handling market research and sales.

The pilot installation runs three independent reactor levels — closed photobioreactors connected in series and stacked vertically. That arrangement is the core engineering constraint: growing cultivation volume by stacking reactors vertically means automation has to reach every stage, from nutrient medium preparation and cultivation through to biomass harvesting.

How does the control system break down?

The plant is organized into separate subsystems, each handling one function:

  • pH control and CO₂ supply
  • suspension withdrawal and centrifuge control
  • medium preparation and photobioreactor filling
  • cleaning and other routine operations

Every subsystem runs in two modes: fully automatic, or operator-controlled, where the operator sets the required parameters and modes. The modular hardware design lets a farm expand by adding sections and rows, with auxiliary equipment capacity scaled to match.

Takeaway: automation here is not one controller but a set of task-specific subsystems, each with an operator override.

What handles medium preparation and filling?

Water enters the process through reverse osmosis purification. Nutrient components are pre-measured and loaded by the operator through a hatch, or delivered by a dedicated pumping unit into preparation tanks. Recirculation mixing then runs automatically on a schedule, after which the required quantity of nutrient solution goes to the photobioreactors.

In the next-generation system, the medium preparation and filling subsystem is built on Siemens LOGO! modules — the small, low-cost logic controllers familiar from building and simple process automation. The subsystem controls purified water supply and nutrient solution delivery and dosing.

At the pilot, the operator starts the supply of water and nutrient solution; filling stops either by operator intervention or automatically when the level is reached, with liquid level monitoring preventing overflow. The new system keeps initial filling under operator supervision but makes subsequent replenishment automatic. Takeaway: the operator's role shrinks to first fill and manual nutrient loading; everything after that runs on the control system.

How are cultivation conditions held?

The measured and controlled parameters are pH, temperature, lighting, CO₂ supply and air for mixing. The physics matters here: microalgae consume CO₂ as photosynthesis feedstock, so pH drifts as the culture grows, and CO₂ dosing doubles as the pH-correction mechanism. A separate subsystem continuously measures suspension pH and temperature and controls CO₂ supply from the pH readings. A heat pump holds the set temperature. Lighting switches on a schedule, and continuous air supply keeps the culture mixed.

Settings depend on the selected culture and biomass requirements, and in the next-generation system the control subsystems monitor and regulate all five parameters independently for each level. Switching to other microalgal species still requires accounting for their biological characteristics and cultivation requirements — the control loops are per-level, not per-species adaptive. Takeaway: per-level independent control is the headline change, letting one farm run different conditions on different levels.

What happens at harvest?

The harvesting subsystem links cultivation to suspension withdrawal. It works from diagnostic characteristics specific to the microalgal species, then initiates delivery of a set suspension volume to the centrifuge, which separates biomass from nutrient solution. The solution returns to the photobioreactors — unless it carries too few remaining nutrients, in which case it goes through reverse osmosis and the purified water lands in reserve tanks for reuse.

Centrifuged biomass can then undergo vacuum drying with controlled heating; loading into the drying chambers is manual, but drying runs automatically on preset parameters. At the pilot, the operator sets the withdrawal volume and chooses the separated liquid's destination — return or discharge — before starting, while the suspension flow measurement subsystem tracks the volume transferred and controls the centrifuge.

The main maintenance operation is washing adhering microalgae off the reactor walls. A dedicated subsystem washes photobioreactors sequentially according to a preset program. The overall system thus covers continuous condition maintenance alongside periodic harvesting and cleaning.

The question the development raises for buyers: with control loops now independent per level and replenishment fully automatic, how much of the seven-year pilot learning curve transfers to farms running species the Tiszasziget team never cultivated?

via algafarms.com (Original)

Filed under

Share this article:

More from Sophie Lindqvist

Sophie Lindqvist

Show full bio

News editor covering regulation, policy and their impact on Instruments, test and measurement at Testbench Report.

113 articles

Application notes