TB-2441 · REV A · Technical newsheet

Sensors & InstrumentationDevice profile

Hamamatsu's RoHS-Compliant InAsSb Detector Targets PbSe Replacement

Hamamatsu's P17442-011MS InAsSb detector cuts off at 5.3 µm, rises in 15 ns, runs uncooled from −40 to +85 °C, and replaces lead-based PbSe parts under RoHS.

By Sophie Lindqvist3 min read590 words

Features

  • Hamamatsu P17442-011MS InAsSb detector: typical 4.1 µm peak sensitivity, 5.3 µm cutoff
  • Typical rise time of 15 ns, uncooled operation over −40 to +85 °C in a TO-5 package
  • 1 × 1 mm active area, larger than previous P16112 and P16612 series; 65 mA/W photosensitivity, D* of 1.0 × 10⁹ cm·Hz¹/²/W
  • RoHS-compliant, lead-, mercury- and cadmium-free alternative to PbSe detectors with greater stability
An RoHS-Compliant InAsSb Detector Offering Greater Stability Than Comparable PbSe Detectors
Device photoAn RoHS-Compliant InAsSb Detector Offering Greater Stability Than Comparable PbSe Detectors — bodkins18 / pixabay

Hamamatsu Photonics has launched an uncooled indium arsenide antimonide (InAsSb) photovoltaic detector, the P17442-011MS, that covers mid-infrared detection out to a typical cutoff wavelength of 5.3 µm — and it does so in a package free of lead, mercury and cadmium. That combination matters because the incumbent technology for this band, lead selenide (PbSe) photoconductors, contains restricted substances and, by Hamamatsu's account, offers less stability. The RoHS-compliant part gives optical system designers a drop-in answer where restricted-substance rules bite.

The headline specs sit squarely in instrument-grade territory. Photosensitivity is typically 65 mA/W, and specific detectivity (D*, the sensitivity figure normalized for detector area and bandwidth) comes in at a typical 1.0 × 10⁹ cm·Hz¹/²/W. Peak sensitivity lands at 4.1 µm. For anyone building gas analyzers, flame detection or process-monitoring optics in the 3–5 µm atmospheric window, those numbers define the usable band.

How fast, and how much light?

Speed is where the part separates itself from thermal detectors. The typical rise time of 15 ns supports fast mid-infrared measurement and rapid signal modulation without any cooling — no thermoelectric cooler, no stirling cycle, no warm-up. Chopped-beam and pulsed-source architectures benefit directly.

The photosensitive area measures 1 × 1 mm, larger than the previous P16112 and P16612 series. More area collects more light, which raises the output signal and eases the burden on the transimpedance amplifier downstream. In practical terms, you trade less optics for the same signal-to-noise ratio.

What's the physics behind the swap?

InAsSb is a III-V compound semiconductor used in photovoltaic mode — it generates a photocurrent at a junction rather than changing bulk resistance as PbSe photoconductors do. Photovoltaic operation carries two consequences that change the buying decision: the response is inherently more linear over a wider dynamic range, and the device doesn't need the bias current that photoconductors require, removing one drift source. Hamamatsu positions the result as high sensitivity, high linearity and greater stability than comparable PbSe detectors. Note that the sensitivity, detectivity and rise-time figures are all typical values from the vendor; Hamamatsu hasn't published test conditions or measured distributions in this announcement, so verify against the datasheet before committing a design.

The back-illuminated structure — light enters through the substrate side — improves temperature sensitivity behavior, the company says. That construction also frees the top surface for contacting.

Packaging and environment

The optical and environmental interface is fully specified:

  • Window and field of view: sapphire window with a 100° field of view
  • Package: high-reliability TO-5 metal can
  • Operating temperature: −40 °C to +85 °C, uncooled
  • Compliance: RoHS; lead-, mercury- and cadmium-free construction

The −40 °C floor covers outdoor and industrial enclosures without heaters. The TO-5 can is a familiar footprint for anyone already routing PbSe or thermopile parts into existing board layouts.

What does this change for designers?

The real question isn't performance parity — on paper the P17442-011MS matches or beats PbSe on speed and stability while eliminating restricted substances. It's qualification. Instrument makers holding legacy PbSe designs now face a compliance decision: grandfather the lead-based detector through exemptions, or requalify an InAsSb photovoltaic front end and absorb the recalibration effort. Hamamatsu's announcement signals it intends to keep pushing this product line forward for exactly that migration. How quickly RoHS pressure in measurement instruments translates into design wins will tell whether PbSe's era in the 3–5 µm band is genuinely closing.

via azosensors.com (Source)

Filed under

  • inassb-detectors
  • mid-infrared-detection
  • rohs-compliance
  • pbse-alternatives
  • photovoltaic-detectors
Share this article:

More from Sophie Lindqvist

Sophie Lindqvist

Show full bio

News editor covering regulation, policy and their impact on Instruments, test and measurement at Testbench Report.

110 articles

Application notes