Design files and a tutorial move power-trace capture off the scope: a CW305 target, a VCU118 with an AD9467 ADC, and a notebook that triggers the DUT and pulls traces over Ethernet.

By Amara Osei4 min read747 words

Features

  • Oscilloscope acquisition of multi-million power traces can take days to months; the FPGA path removes that bottleneck.
  • Setup pairs a CW305 target with a VCU118 board carrying an AD9467 ADC on the FMC interface.
  • Bitfiles 305_top.bit (for xc7a100tftg) and vcu118_capture_top.bit; other Artix-7 boards require recompilation.
  • PMOD J52 wiring: A15 to pin 1, D16 to pin 2, E15 to pin 3, B14 to pin 5, GND to pin 9.
  • LED 5 lights high while the board waits for the DUT; traces reach the host over Ethernet.
Capturing Power Traces using VCU 118 and AD9467 FMC
Device photoCapturing Power Traces using VCU 118 and AD9467 FMC — 2427999 / pixabay

Capturing a million-plus power traces on an oscilloscope can take days to months, according to the author of this project; the same acquisition, split between a CW305 target and a VCU118 board carrying an AD9467 ADC, ends as files arriving over Ethernet for a notebook to collect. The bottleneck was never the DUT. It was the instrument.

What does the setup actually contain?

Two prebuilt bitfiles do the heavy lifting. 305_top.bit targets the xc7a100tftg Artix-7 device, and vcu118_capture_top.bit handles the capture side; anyone on a different Artix-7 board has to recompile for their specific version. The CW305 runs the device under test, and the VCU118 probes that device's power trace.

The author describes the result plainly: the VCU118, "equipped with AD9467 ADC," probes the DUT and transfers "the traces from FPGA to host computer." Design files and constraints sit in a GitHub repository, and the tutorial stretches past power probing to show how to drive the ADC and Ethernet blocks on the VCU118 in general.

Takeaway: one bitstream pair covers target and capture, but the board-specific rebuild keeps this out of plug-and-play territory.

How is the hardware wired?

The AD9467 board plugs into the VCU118 FMC interface, and three point-to-point connections carry the session:

  • CW305 clock out at T13 to ADC J201
  • CW305 X4 to ADC J100
  • PMOD signals through CW305 J52 into the VCU118

The PMOD map is the fiddly part, and the tutorial gives it as a straight list: A15 lands on J52 pin 1, D16 on pin 2, E15 on pin 3, B14 on pin 5, and GND on pin 9. An Ethernet cable runs to the host computer, and LED 5 lights high while the board waits for the DUT to start.

Clock selection is the one deliberate freedom in the wiring. The default is the FPGA-generated sampling clock, but the tutorial notes you can feed in an external clock generator for a higher frequency, which is the knob that sets how fast the converter must digitize the DUT's supply activity.

Takeaway: the pin list is short and explicit; the clock source is where you buy temporal resolution.

What does a run actually produce?

Run the notebook. It carries the DUT's input, load and output capture, triggers the DUT on the CW305, and collects traces coming back over Ethernet. The author posts the wired-up setup and one sample collected trace for the record.

Now the part a metrologist will ask about. The repository publishes no sampling rate, no converter resolution, no effective number of bits, no calibration interval and no measured accuracy, and it states no test conditions, because it reports no measurements.

The only observable states in the write-up are LED 5 high at idle and that single sample trace. Treat every performance expectation as unverified until you pull your own numbers on the bench.

The physics sets the buying decision anyway. Side-channel work reads the DUT's supply current, whose ripple follows internal switching and carries key-dependent structure; the ADC digitizes that analog current into a sampled record, and the sampling clock fixes the highest frequency that record can hold.

Push the clock faster and the ceiling rises, but only if the converter can sustain the rate — otherwise high-frequency content folds back into the band as aliasing, which looks like signal.

Trace depth is the other axis. A campaign needing multi-million traces spends its time in memory and transport, which is precisely the days-to-months problem the FPGA path sidesteps. The author frames the rationale in one line: "We can get rid off the bottleneck using FPGAs which supports ADC."

Takeaway: the capture pipeline is documented; the converter's measured performance is not.

Is it ready to adopt?

For a side-channel researcher the question is not whether the plumbing works — the author's setup photo suggests it does — but whether the unstated converter performance suits a specific campaign. Set the required sample rate, trace depth and alignment tolerance first, then check what the clocking in the repo can actually deliver.

An external clock generator raises that rate, but nothing published here says how far it goes or what it costs in noise and settling time. The design files are worth the afternoon. The performance table is worth writing yourself.

Takeaway: adopt the pipeline, but budget a day to characterize the converter before a campaign trusts it.