Features

  • SinceVision specifies 0.05 µm repeatability (diffuse white target, static) and ±0.02% FS linearity for the SGI-N030W.
  • The sensor samples at 50 kHz (20 µs update interval) over a ±5 mm range at a 30 mm reference distance.
  • Production trials on battery electrodes showed thickness measurement within ±0.3 µm at a 300 mm/s web speed.
  • Master-slave synchronisation allows two opposed sensors on a marble gantry to compute absolute thickness in real time.
  • Interfaces include RS485, 100Base-TX Ethernet and switchable 4–20 mA / 0–10 V analogue outputs.
SinceVision Launches Wide-Spot Laser Displacement Sensor for Precision Measurement
Device photoSinceVision Launches Wide-Spot Laser Displacement Sensor for Precision Measurement — jarmoluk / pixabay

SinceVision specifies 0.05 µm repeatability, ±0.02% FS linearity and a 50 kHz sampling rate for its new SGI-N030W wide-spot laser displacement sensor, aimed at non-contact dimensional measurement on rough, textured and irregular surfaces. The company reports production-trial thickness measurement within ±0.3 µm at a 300 mm/s web speed in lithium-ion battery electrode inspection.

The sensor extends the existing SGI Series portfolio and targets lithium-ion battery manufacturing, semiconductor processing and precision mechanical engineering, where micrometre-level measurement is required.

Why the wide spot changes the measurement

Conventional point-spot laser displacement sensors concentrate reflected laser energy onto a small area. On surfaces with scratches, grain boundaries, brushed textures or matte finishes, microscopic features introduce signal variations that the sensor interprets as dimensional changes. The result: false defect warnings and additional manual inspection.

The SGI-N030W counters this with a wide-spot optical configuration and triangulation. By collecting reflected light across a broader surface area, the sensor averages localised microscopic peaks and valleys before signal conversion. This reduces the influence of surface roughness and optical scattering, and SinceVision reports more stable displacement measurements on drawn metals, sandblasted surfaces and coated battery foils. These figures are vendor specifications, obtained with a diffuse white target under static conditions; the company did not publish test data for the textured materials it names.

What are the headline specifications?

  • Reference distance: 30 mm
  • Measurement range: ±5 mm
  • Repeatability: 0.05 µm (diffuse white target, static conditions)
  • Linearity: ±0.02% of full scale
  • Sampling frequency: 50 kHz, equivalent to a 20 µs update interval
  • Interfaces: RS485, 100Base-TX Ethernet, switchable analogue output at 4–20 mA or 0–10 V

The system also provides master-slave synchronisation, allowing two sensors to operate in opposition for simultaneous measurement from either side of a component or moving material.

How does it measure electrode thickness in line?

Coating thickness and uniformity are critical parameters in battery cell manufacturing; they influence energy density, internal resistance and long-term cell stability. Conventional offline inspection with contact micrometers or drop indicators introduces operator variability and can deform wet or uncured electrode materials. Periodic spot checks also cannot deliver continuous coverage across an entire production reel.

The proposed arrangement places two synchronised sensors above and below a moving electrode web, mounted on a calibrated, low-thermal-expansion marble gantry. The opposing heads measure their respective clearances to the material, and a system controller combines these readings with the fixed mounting datum to calculate absolute electrode thickness in real time.

According to SinceVision, production trials demonstrated stable, repeatable thickness measurement within ±0.3 µm at a web speed of 300 mm/s. The 50 kHz sampling rate provides high longitudinal resolution, enabling detection of localised coating agglomerations, edge thinning and exposed substrate areas before the material reaches cell winding.

What roles does it fill beyond batteries?

In semiconductor manufacturing, the sensor suits non-contact tasks on sensitive wafer surfaces: wafer position verification, edge detection, height measurement, and checking wafer seating and chuck alignment in atmospheric transfer modules and vacuum load-lock systems.

In precision assembly, it can monitor the dynamic movement of voice coil motors, linear actuators and micro-steppers. The 50 kHz rate captures transient displacement, mechanical oscillations, settling behaviour and end-stop overshoot across the full measurement range. Position data can be transmitted to machine control systems through the Ethernet interface for real-time monitoring and process control.

What does the vendor claim versus what is verified?

Jack Li, Global Sales and Marketing Director at SinceVision, said false defect warnings caused by surface texture remain a recurring challenge in battery manufacturing and precision assembly. He explained that conventional point-beam laser sensors can interpret microscopic scratches and rough coatings as actual thickness variations, slowing production lines and creating a need for additional manual inspection.

The SGI-N030W's expanded optical spot is designed to average out these surface-related variations, Li said, while synchronisation between opposing sensor heads supports high-speed thickness verification.

The reported ±0.3 µm electrode thickness result comes from the vendor's own production trials; no independent or third-party test data accompanies the launch. Buyers evaluating the sensor against interferometric or confocal alternatives will need to verify repeatability on their own production materials, since the 0.05 µm figure applies only to a diffuse white target under static conditions.

Whether the wide-spot averaging approach holds its specified stability on coated battery foils and sandblasted metals — and whether it can displace contact micrometry in high-volume electrode lines — is the adoption question battery manufacturers will now test.

via sincevision.com (Original)

Filed under

  • laser-displacement-sensor
  • non-contact-measurement
  • thickness-inspection
  • battery-manufacturing
  • precision-engineering
Share this article:

More from Nathan Brooks

Nathan Brooks

Show full bio

Staff writer covering people, launches and day-to-day practice in Instruments, test and measurement at Testbench Report.

105 articles

Application notes

« Previous articleNext article »